Currently Empty: $0.00
Curriculum
- 7 Sections
- 76 Lessons
- 7 Hours
Expand all sectionsCollapse all sections
- Module 01 Introduction2
- Module 02 Quantity Take off for Sub-structure17
- 2.1Lesson 2.1 How to measure site clearance in CostX
- 2.2Lesson 2.2 How to add New Drawing and measure blinding in costX
- 2.3Lesson 2.3 How to add Multiple drawings in CostX
- 2.4Lesson 2.4 Calculation for Pad Footing
- 2.6Lesson 2.5 How to measure concrete in stub columns
- 2.7Lesson 2.6 How to take off formworks for footings
- 2.8Lesson 2.7 how to calculate formworks for stub columns
- 2.9Lesson 2.8 How to measure concrete for ground beams
- 2.10Lesson 2.9 How to measure concrete for slabs
- 2.11Lesson 2.10 How to create and upload rebar constants in CostX
- 2.12Lesson 2.11 How to take off rebar for footings in costX
- 2.13Calculation for GB Concrete
- 2.14Calculation for Formwork GB
- 2.15Calculation for Ground Slab PCC
- 2.16Calculation for Ground Slab Concrete
- 2.17Calculation for Anti-Termite Treatment
- 2.18Calculation for Sand Filling
- Quantity Take off for Super Structure15
- 3.1Manual and Automatic Dimension Group Creation
- 3.2Calculation for Column Concrete Ground FL
- 3.3Calculation for Stair Concrete-Ground FL
- 3.4Calculation for Column Formwork-Ground FL
- 3.5Calculation for Stair Formwork-Ground FL
- 3.6Calculation for Beam Concrete-1st-FL
- 3.7Calculation for Beam Formwork-1st FL
- 3.8Calculation for Column Concrete-1st FL
- 3.9Calculation for Column Formwork-1st FL
- 3.10Calculation for Slab Concrete-1st FL
- 3.11Calculation for Slab Formwork-1st FL
- 3.12Calculation for Stair Concrete-1st FL
- 3.13Calculation for Roof Beam Concrete
- 3.14Calculation for Roof Beam Formwork
- 3.15Calculation for Roof Slab Concrete and Formwork
- Quantity Take off for Architectural12
- 4.1How to Scale the Drawing
- 4.2Dimension Group Creation
- 4.3Calculation for Brick Wall 200mm External
- 4.4Calculation for Brick Wall_150mm External
- 4.5Calculation for Brick Wall_150mm Internal
- 4.6Calculation for Brick Wall Plaster External
- 4.7Calculation for Brick Wall Plaster_Internal
- 4.8Calculation for Paint Work_External
- 4.9Calculation for Paint Work_Internal
- 4.10Calculation for Water Proofing
- 4.11Calculation for Floor Finishes
- 4.12Calculation for Wall Skirting
- Reinforcement Quantity Take off5
- Quantity Take off for MEP ( Mechanical , Electrical , Plumbing )18
- 6.1Create Dimension Group
- 6.2Calculation for Equipment
- 6.3Calculation for Wall Mounted AC Unit
- 6.4Calculation for EAD
- 6.5Calculation for RAD
- 6.6Calculation for SAD
- 6.7Calculation for 20A Grid Switch
- 6.8Calculation for Ceiling Fan
- 6.9Calculation for Surface Mounted LED Light
- 6.10Calculation for Cable Tray
- 6.11Calculation for Cable Length
- 6.12Calculation for 15 mm dia CWS
- 6.13Calculation for 22 mm dia CWS
- 6.14Calculation for 28 mm dia CWS
- 6.15Calculation for 28 mm dia L-Angle
- 6.16Calculation for 28 mm dia T
- 6.17Calculation for 54 mm dia CWS
- 6.18Calculation for Isolation Valve
- BOQ7

